Portable Patient Monitor

Other Characteristics Continuous, High-Resolution, Plug-In Module
Measured Parameter Ecg, Resp, Temperature, Heart Rate, Etco2, Nibp, Spo2
Configuration Portable, Modular
Applications Veterinary, For Animal Research
Patient Condition For High Blood Pressure, For Sleep Apnea
Technology Pulse Wave Analysis, Abi, Tbi
Options And Accessories Wifi, With Touchscreen, With Built-In Printer, With Usb Port, With Patient Data Management System, With Spirometry
SKU: 69d1f06b43ee Category: Tags: , ,
Description

Monitoring parameters include HR, ECG, SPO2, NIBP, RESP, TEMP, and CO2.input:
output:Data storage that exceeds 1200 hoursinput:
output:Mainstream/bypass ETCO2 interface as standardLCD display with a resolution of 1280*800.

Mainstream/bypass ETCO2 interface as standardOperational interface that supports more than five languages (optional)Twenty types of arrhythmia event alarms are supported, as well as the ST segment analysis function.

The printing function is triggered, and each abnormality is recorded in real time.

High-capacity lithium battery, with a continuous operating time of at least 300 minutes.

Grid, inotropic interference, anti-defibrillation, and electric knifeinput:
output:Accessories:Five-lead heart wire*1Body surface temperature probe*1Blood oxygen probe*1One extension tube for blood pressure*Four disposable blood pressure cuffsTwenty-five disposable electrode sheets or clipsElectrocardiogram (ECG):Lead selection: standard three-/five-lead; up to seven leads can be displayed on the same screen. â… , â…ˇ, â…˘, AVR, AVL, AVF, V chest leads

Value detection range for electrocardiograms: 15 to 350 beats per minute

Resolution: 1 beats per minuteAccuracy of measurement: ±2% or ±2bpm, whichever is greater.Frequency response: 0.67 Hz to 40 Hz

Monitoring of the S-T segment: -2.0 mV to 2.0 mV

Electrode off indication: light and sound prompt

Scan speed: 6.25, 12.5, 25, and 50mm/sec.Gain selection: Ă—0.125, Ă—0.25, Ă—0.5, Ă—1, Ă—2, Ă—4, automatic

ECG calibration: 1mV + 5%

Protection isolation is capable of withstanding a voltage of 4000V/AC/50Hz.ECG cable lead wire: 3/5 leadA universal ECG cable with five leads and a buckle type is the standard configuration.Configuration: research-specific ECG cable cable, (custom small clip)Alarm: Alarm value upper and lower limits can be preset, with automatic memory and alarm review.Oxygen saturation:Display: Oximetry value, pulse bar graph, waveform, pulse valueOximetry range: 0%-100% for equines, canines, and felines.

 

 

Shipping & Delivery

MAECENAS IACULIS

Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.

ADIPISCING CONVALLIS BULUM

  • Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
  • Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
  • Diam parturient dictumst parturient scelerisque nibh lectus.

Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.