Digital Refractometer
Configuration | Benchtop |
Applications | Laboratory, For The Sugar Industry |
Type | Digital |
Other Characteristics | Peltier Effect, With Automatic Temperature Correction |
RX4 Refractive Index Cellinput:
output:The RX4 Refractive Index Cell can be incorporated into an Excellence Density meter to simultaneously measure the refractive index and density. The refractive index is measured by the RX4 in the range of 1.32 to 1.70, with automatic temperature control from 0 to 100°C.Specificationsinput:
output:Brix measurement range: 0–100% w/w
Accuracy Brix: % w/w
Scales of measurement include the Refractive Index, Sugar (Brix and beyond), Acid/Base, Chemical, Freezing Point, Salt, and others.Concentration tables that are user-defined may be entered as either tables or formulas, with a maximum of 30.
Weight: 4.8 kilograms
nD measurement range: 1.3200 – 1.7000
Precision nD (±): 0.0001
Temperature control range: 5°C to 100°CW x H x D – 226 x 193 x 208 mmLIMS connectivity: Certainly.Main norms and standards: AOAC 969.18,AOAC 943.05,OIV MA-AS2-02,UOP 816,AOAC 932.14, Section C,ICUMSA SPS-3 (2000),ASTM D3321,Ph. Eur. 2.2.6,AOAC 983.01,AOAC 948.10,AOAC 945.102,AOAC 969.38,ASTM D4095,ASTM D1747,AOAC 905.01,AOAC 976.20,AOAC 920.141,AOAC 896.02,AOAC 898.02,ASTM D5006,AOAC 950.13,ISO 280,GBT 10786-2006,USP 831,AOAC 921.08,AOAC 970.15,AOAC 970.59,ASTM D2140,AOAC 920.78,ASTM D4542,ASTM D 1807,A.O.C.S. Official method Cc7-25,OIML R 108,AOAC 983.17,OIV MA-AS312-01B,AOAC 953.16,AOAC 2000.19,AOAC 950.04,AOAC 940.09,AOAC 932.12,ASTM D524,GB/T 12143-2008,ICUMSA GS4/3 – 13 (2004),ISI 06-1e,ASTM D1218
Repeatability Brix (% w/w): 0.05 % w/wRepeatability nD (±): 5e-005
Temperature regulation: Yes
Accuracy of temperature control (±): 0.1 °CUser Management: Yes


MAECENAS IACULIS
Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.
ADIPISCING CONVALLIS BULUM
- Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
- Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
- Diam parturient dictumst parturient scelerisque nibh lectus.
Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.
Related products
Digital Microscope
Fluorescence Immunoassay Poc Analyzer
Hospital Door
Inverted Microscope
Type | Optical |
Observation Technique | Fluorescence, Phase Contrast, Polarized, Dic |
Other Characteristics | High-Resolution |
Ergonomics | Inverted |
Applications | Laboratory, For Research, For Biology, For Brain Imaging, For Teaching, Multifunctional |
Configuration | Benchtop |
Quality Of The Objectives | Plan Achromatic, Plan, Infinity Corrected, Apochromatic, Semi-Apochromat, Semi-Plan |
Light Source | Led, Halogen |
Options And Accessories | With Color Camera, Usb Camera, With Micromanipulator, Computer-Assisted |
Optical Microscope
Pharmacy Refrigerator
Upright Microscope
Type | Optical |
Observation Technique | Fluorescence, Phase Contrast, Dark Field, Polarized, Dic |
Microscope Head | Trinocular |
Ergonomics | Upright |
Applications | Laboratory, For Research, Clinical, Veterinary Laboratory, Multifunctional |
Configuration | Benchtop |
Quality Of The Objectives | Achromatic, Plan Achromatic, Plan, Infinity Corrected, Apochromatic, Semi-Apochromat, Semi-Plan |
Light Source | Led, Uv |
Options And Accessories | Usb Camera, Motorized |