Type Of Analysis | Cardiac |
Options | With Treadmill, With Exercise Bike |
The CARDIOVIT CS-104 is a comprehensive system that integrates all necessary ECG features and desired capabilities.input:
output:The system comprises a wireless (MS-12 blue) or wired (MS-12 USB) acquisition module, a trolley, a monitor, and a PC. An alternative method of ECG acquisition is the utilization of the CARDIOVIT FT-1. SCHILLER has pre-installed and tested all components, ensuring that they are prepared for use in the clinical setting.input:
output:CARDIOVIT CS-104 is also accessible as resting ECG PC software, with the option of stress test and spirometry add-ons.Features:
– The automatic interpretation for athletes is available with the SCHILLER ECG analysis program ETM and ETM Sport, which includes the resting ECG.
– Optional arrhythmia detection, with a recording of the resting rhythm for up to 60 minutes
– ECG Framer: A 10-second resting ECG that is extracted from the resting rhythm, complete with measurements and interpretation.- Optional arrhythmia detection during an exercise stress test- Pharmacological stress test- Vector ECG, optional
– Optional spirometry, which is based on the ultrasound technology of the SpiroScout SP plus
– User interface that is both customizable and intuitive: Select from a variety of ECG views, enable or disable trend charts, and select action buttons.
– A workstation that is integrated to allow for the review of ECG and spirometry recordings from all SCHILLER devices that are connected to the SCHILLER Server.- Bidirectional connectivity to EMR, HIS, and PACS systems, including worklist and PDQ.- Trolley with a spring mechanism that allows for an adjustable working height of 88 to 122 cm


MAECENAS IACULIS
Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.
ADIPISCING CONVALLIS BULUM
- Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
- Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
- Diam parturient dictumst parturient scelerisque nibh lectus.
Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.
Related products
2-Channel Emg Monitoring System
20-Channel Eeg System
Compact Patient Monitor
Other Characteristics | Continuous, Non-Invasive |
Measured Parameter | Ecg, Resp, Temp, Heart Rate, Etco2, Nibp, Ibp, Cardiac Output, Eeg, Spo2 |
Configuration | Portable, Compact |
Applications | Intensive Care, Clinical |
Technology | Pulse Wave Analysis |