32-Channel Eeg System
Number Of Channels | 32-Channel, 64-Channel, 128-Channel |
Primarily designed for neuroscientific applications, the NEURO PRAX® EEG is a full-band DC-EEG system. The system simultaneously and synchronously measures physiological signals, including EEG, EMG, and EP, within the frequency range of 0 to 1,200 Hz for all channels. The amplifier technology is distinctive in that it captures EEG activities at frequencies ranging from infraslow (0–0.3 Hz) to ultrafast (80–1,200 Hz).
We are capable of providing our high-performance full-band DC amplifiers with 32, 64, or 128 channels. The neuroConn software is intuitive, flexible, and user-friendly, as it is specifically designed to work with the hardware. Online correction of artifacts caused by muscle and eye movements, topographical analyses, spectral and amplitude mapping, and online averaging are among the numerous software and hardware modules that are available.input:
output:CE-certified as a biofeedback and neurofeedback system
CE-certified, the NEURO PRAX® EEG is a bio- and neurofeedback system. It concentrates on the training of slow cortical potentials (SCP) and frequency training. Biofeedback is a treatment method that is derived from operant conditioning. The patient is primarily unable to perceive the feedback regarding their physiological states and the changes that occur as a result of this method.
Instrument-based behavioral therapy employs neurofeedback, which is a form of biofeedback. It enables patients to self-regulate and perceive their brain activity. The NEURO PRAX® EEG is capable of providing neurofeedback to children who have a brain that is unable to regulate its own activity. This impairment may be observed at the neurological and/or behavioral levels, as evidenced by ADHD.


MAECENAS IACULIS
Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.
ADIPISCING CONVALLIS BULUM
- Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
- Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
- Diam parturient dictumst parturient scelerisque nibh lectus.
Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.
Related products
Trolley-Mounted Patient Monitor
Other Characteristics | Continuous, Non-Invasive, High-Resolution, Easy-To-Use, Oscillographic |
Measured Parameter | Respiratory Frequency, Ecg, Temperature, Heart Rate, Etco2, Cardiac Output, Blood Pressure, Eeg, Pressure, Co, Systolic Pressure, Perfusion Index, Pulse Oximetry |
Configuration | Portable, Compact, Modular, Bedside, Mobile, All-In-One Workstation, Trolley-Mounted |
Applications | Clinical, Intensive Care, Emergency, Ambulatory, For Hospitals, For Surgery Units, Home Care, For Research, For Nursing Homes, Oscillographic, For Telemedicine |
Patient Condition | For High Blood Pressure, For Arrythmia, For Sleep Apnea |
Technology | Pulse Wave Analysis |
Options And Accessories | With Touchscreen, Wireless, With Built-In Printer, With Usb Port, With Patient Data Management System, With Integrated Thermal Printer, With Diagnosis Software |